Home arrow Chromatogram Processor
Chromatogram Processor
TECD Algorithm

The TECD (Total Extraction Component Detection) algorithm creates spectral trees for every section of a chromatogram that starts with an MS1 scan. Each generated tree is then divided into sub-trees based on the value of the Minimal Tree Depth parameter. Generated sub-trees are merged into components based on the precursor ion m/z value identity and the spectral tree match factor similarity.

 

To start automated component detection and the spectra deconvolution procedure using TECD algorithm:

  1. Click on the Components Detection and Spectra Deconvolution button and choose the TECD pop-up menu item

  2. When the parameters setup dialog window appears, change the settings if required, and then click the Calculate button

The TECD algorithm dialog window contains various parameters that can be optimized for specific types of analysis. Please note that these parameters are interdependent, so a change of one parameter can also affect algorithms linked with other parameters.

 

Note:

These parameters are interdependent, so a change of one parameter can also affect algorithms linked with other parameters.

 

 

Minimal Tree Depth: Specifies the minimum number of tree sections the algorithm will create from the initial spectral tree. The value determines the MS stage where a division takes place.

Tree Match Factor: Specifies the minimum percentage that two spectral trees within adjacent tree sections must match before the algorithm will consider the two spectral trees as the same component. Matching spectral trees are defined as having identical precursors up to the level specified by the Minimal Tree Depth value and a Tree Match Factor value that exceeds the specified value.

Wide Component Merge Mode: Enables a comparison of the spectral trees for potential matching and merging, not only in adjacent sections, but also in sections up to the distance specified by the Allowed Gap value.

Allowed Gap: Specifies the maximum distance between nonadjacent tree sections over which to compare the spectral trees for potential merging.

Retention Time Range: Allows you to specify only a part of a chromatogram to be analyzed (time range), which can speed up your work. In this case, the algorithm ignores regions outside of the specified range

m/z Range: Allows you to specify only a part of a chromatogram to be analyzed (m/z range), which can speed up your work. In this case, the algorithm ignores regions outside of the specified range.

 

 

 
Direct Infusion

The Direct Infusion algorithm is a spectral tree construction utility rather than a component detection method. It allows the creation of one or more spectral trees from a single raw file by the reading of various MSn scans acquired in one run and constructing a tree according to their MS stage and precursor ion m/z values.

 

To start the spectral tree construction utility using Direct Infusion algorithm:

  1. Click on the Components Detection and Spectra Deconvolution button and choose the Direct Infusion pop-up menu item

  2. When the parameters setup dialog window appears, change the settings if required, and then click the Calculate button

The Direct Infusion algorithm dialog window contains various parameters that can be optimized for specific types of analysis. Please note that these parameters are interdependent, so a change of one parameter can also affect algorithms linked with other parameters.

 

Note:

These parameters are interdependent, so a change of one parameter can also affect algorithms linked with other parameters.

 

 

Minimal Tree Depth: Specifies the MS stage that should only have a single precursor . The value determines the MS stage where a tree branch division will take place. If the default value 1 is used, the algorithm creates a single tree from all the scans in a run (file). If the value 2 is used and the analyzed run contains MS2 spectra with different precursor m/z values, the algorithm will create separate trees for each MS2 scan with a unique precursor ion m/z value.

Include Upper Spectra: If checked, the resulting spectral trees contain actual scans in the stage above the level set in Minimal Tree Depth. If unchecked, the spectra above the stage set in Minimal Tree Depth. contain spectra with a single peak equal to the precursor ion of the product spectra.

Average Scan: If checked, every tree node will only contain average spectra.

Calculate Envelope: If checked, the ion profile (envelope) for each tree will be calculated. This allows you to preview scans that belongs to particular tree.

 

 
Processing of Extracted Spectra

A spectrum obtained from the average of scans, or from scans with a subtracted background, or from component deconvolution, can be further processed in Database Manager, Spectra Classifier, or can be directly searched for in a library from Chromatogram Processor. To transfer the extracted spectrum or tree to Database Manager or Spectra Classifier, use the copy button. After pressing the copy button in the Chromatogram Processor window, the mass spectrum can be pasted to a Database Manager or Spectra Classifier window. In addition, when you press the copy button in the Chromatogram Processor, the chromatogram graphic along with the spectrum from the Scan tab will be copied to Windows Clipboard and can be used for creating reports in any Windows application.

 

The Chromatogram Processor window contains a Search button for the direct searching of spectrum from the Scan tab or tree from the Tree pane in libraries. To search the extracted spectrum in libraries, just press the Search button in the Chromatogram Processor window and the Spectra Search dialog window will appear.

 

Mass Spectra obtained in Chromatogram Processor can be classified using Principal Component Analysis, Neural Networks, and Fuzzy Clustering methods.

To choose scans or deconvoluted spectra for classification:

 

 
Working with Detected Components

Detected components are marked with a triangle in the original chromatogram. Because the program calculates the precise retention time (tR) of each component the component triangle can appear between scan points.

 

Note:

To display a deconvoluted spectrum of a component rather than of a scan, click the triangle that marks the detected component in the chromatogram pane. To display an original scan at the position of a detected component, you should click above the triangle.

 

 

If you select a component by clicking its triangle, a deconvoluted spectrum will appear in the spectrum pane. This spectrum can be processed in the same way as any spectra in the program, e.g. searched in a library or copied to Database Manager.

If you move the mouse cursor over a component triangle, a tool tip rectangle will inform you about the component number, precise retention time and model ion m/z value that were used in the automated detection and deconvolution processes.

 

Chromatographic components can be edited or searched in Components Editor that can be opened using Edit Components    button.

 

To copy or process more than one detected component in Database Manager or in Spectra Classifier modules, you must first select them.

To select one or more components:

  • Click on the Select Scans or Components button image\ButGCLCMSSelComp.gif and select the desired components with the mouse cursor while holding down the LEFT mouse button

 

To select all detected components in a run:

  1. Click anywhere in the chromatogram pane with the RIGHT mouse button and a pop-up menu will appear.

  2. Click on the Select All menu item.

 

The program makes a strict distinction between original scans and detected components and does not mix them. When selecting a chromatographic region, components are preferred over scans. If you select a chromatographic region that contains components, only these components will be selected. If you select a region that does not contain any components, all scans in that region will be selected.

 

 
Processing MSn Data

Chromatogram Processor allows you to view and process Xcalibur® data dependent experiments and product ion scanning *.raw files and extract spectral trees (MSn spectra) from chromatograms. If Xcalibur® data is opened in Chromatogram Processor, a tree view control will appear on the right side of the window. This tree view control allows you to select one or more product scans at any MSn stage. If deconvoluted components are present, they are listed at the bottom of the tree control.

 

If component detection and spectra deconvolution procedure is applied to data dependent chromatograms, the program generates components as spectral trees. The tree components can be processed in the same way as regular spectra. They can be edited in Components Editor, searched in spectral libraries or classified using Spectra Classifier. Spectral trees in Chromatogram Processor can only be viewed. If you wish to edit them, you must copy and paste them into Database Manager, where all editing utilities are available.

 

Please note that the spectrum in the bottom right of the Chromatogram Processor window is displayed for the selected tree node spectrum.

 

 

Spectral Tree is a trademark of HighChem, Ltd., Slovak Republic

Xcalibur® is a registered trademark of Thermo Electron.

 
<< Start < Prev 1 2 3 Next > End >>

Results 19 - 24 of 24